D3C6182Y-4K
RM14,426.00
The D3C6182Y-4K RF circulator operates across the 6.10–8.20 GHz frequency range. It provides 22 dB minimum isolation, 0.5 dB maximum insertion loss, and 16 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 20 W average power RF circulator supports up to 30 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 4 K and has a maximum weight of 1.0 oz, supporting stable RF performance in ultra-low temperature cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female...
D3C6182Y-4KD3C6182Y-4K-1D3C6182Y-4K-2D3C6182Y-4K-3D3C6182Y-4K-4D3C6182Y-4K-5D3C6182Y-4K-6D3C6182Y-4K-7
D3C6282Y-4K
RM14,426.00
The D3C6282Y-4K RF circulator operates across the 6.20–8.20 GHz frequency range. It provides 28 dB minimum isolation, 0.3 dB maximum insertion loss, and 24 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 20 W average power RF circulator supports up to 30 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 4 K and has a maximum weight of 2.0 oz, supporting stable RF performance in ultra-low temperature cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female...
D3C6282Y-4KD3C6282Y-4K-1D3C6282Y-4K-2D3C6282Y-4K-3D3C6282Y-4K-4D3C6282Y-4K-5D3C6282Y-4K-6D3C6282Y-4K-7
D3C6282YMG-4K
RM14,932.00
The D3C6282YMG-4K RF circulator operates across the 6.20–8.20 GHz frequency range. It provides 28 dB minimum isolation, 0.3 dB maximum insertion loss, and 24 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 20 W average power RF circulator supports up to 30 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is magnetically shielded and optimized for operation below 4 K, supporting stable RF performance in ultra-low temperature cryogenic systems. The unit has a maximum weight of 2.0 oz.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male...
D3C6282YMG-4KD3C6282YMG-4K-1D3C6282YMG-4K-2D3C6282YMG-4K-3D3C6282YMG-4K-4D3C6282YMG-4K-5D3C6282YMG-4K-6D3C6282YMG-4K-7
D3C6313Y-77K
RM10,126.00
The D3C6313Y-77K RF circulator operates across the 6.30–13.75 GHz frequency range. It provides 12 dB minimum isolation, 1.0 dB maximum insertion loss, and 12 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 77 K and has a maximum weight of 1.0 oz, supporting stable RF performance in cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C6313Y-77K-1.
D3C6313Y-77KD3C6313Y-77K-1D3C6313Y-77K-2D3C6313Y-77K-3D3C6313Y-77K-4D3C6313Y-77K-5D3C6313Y-77K-6D3C6313Y-77K-7
D3C6313YMG-77K
RM10,629.00
The D3C6313YMG-77K RF circulator operates across the 6.30–13.75 GHz frequency range. It provides 12 dB minimum isolation, 1.0 dB maximum insertion loss, and 12 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is magnetically shielded and optimized for operation below 77 K, supporting stable RF performance in cryogenic systems. The unit has a maximum weight of 1.0 oz.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female...
D3C6313YMG-77KD3C6313YMG-77K-1D3C6313YMG-77K-2D3C6313YMG-77K-3D3C6313YMG-77K-4D3C6313YMG-77K-5D3C6313YMG-77K-6D3C6313YMG-77K-7
D3C6512Y-77K
RM13,920.00
The D3C6512Y-77K RF circulator operates across the 6.50–11.90 GHz frequency range. It provides 12 dB minimum isolation, 0.8 dB maximum insertion loss, and 12 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 10 W average power RF circulator supports up to 30 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 77 K and has a maximum weight of 0.9 oz, supporting stable RF performance in cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C6512Y-77K-1.
D3C6512Y-77KD3C6512Y-77K-1D3C6512Y-77K-2D3C6512Y-77K-3D3C6512Y-77K-4D3C6512Y-77K-5D3C6512Y-77K-6D3C6512Y-77K-7
D3C6913Y-4K
RM10,629.00
The D3C6913Y-4K RF circulator operates across the 6.90–13.60 GHz frequency range. It provides 16 dB minimum isolation, 1.0 dB maximum insertion loss, and 12 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 4 K and has a maximum weight of 1.0 oz, supporting stable RF performance in ultra-low temperature cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female...
D3C6913Y-4KD3C6913Y-4K-1D3C6913Y-4K-2D3C6913Y-4K-3D3C6913Y-4K-4D3C6913Y-4K-5D3C6913Y-4K-6D3C6913Y-4K-7
D3C6913YMG-4K
RM11,135.00
The D3C6913YMG-4K RF circulator operates across the 6.90–13.60 GHz frequency range. It provides 16 dB minimum isolation, 1.0 dB maximum insertion loss, and 12 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is magnetically shielded and optimized for operation below 4 K, supporting stable RF performance in ultra-low temperature cryogenic systems. The unit has a maximum weight of 1.0 oz.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male...
D3C6913YMG-4KD3C6913YMG-4K-1D3C6913YMG-4K-2D3C6913YMG-4K-3D3C6913YMG-4K-4D3C6913YMG-4K-5D3C6913YMG-4K-6D3C6913YMG-4K-7
D3C7011
RM2,661.00
The D3C7011 RF circulator operates across the 7.00–11.00 GHz frequency range. It provides 20 dB minimum isolation, 0.5 dB maximum insertion loss, and 1.25:1 minimum VSWR to maintain controlled RF signal transmission within the specified frequency band.This 15 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing and protection. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, brass load body, and nickel plated CRS magnetic shunt.The circulator operates within -30°C to +85°C and has a maximum weight of 1.0 oz, supporting reliable operation in RF and microwave environments.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C7011-1.
D3C7011D3C7011-1D3C7011-2D3C7011-3D3C7011-4D3C7011-5D3C7011-6D3C7011-7
D3C7012
RM2,661.00
The D3C7012 RF circulator operates across the 7.00–12.40 GHz frequency range. It provides 18 dB minimum isolation, 0.5 dB maximum insertion loss, and 1.3:1 minimum VSWR to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing and protection. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, brass load body, and nickel plated CRS magnetic shunt.The circulator operates within -30°C to +85°C and has a maximum weight of 1.0 oz, supporting reliable performance in RF and microwave environments.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C7012-1.
D3C7012D3C7012-1D3C7012-2D3C7012-3D3C7012-4D3C7012-5D3C7012-6D3C7012-7
D3C7012Y-4K
RM14,426.00
The D3C7012Y-4K RF circulator operates across the 7.20–11.90 GHz frequency range. It provides 12 dB minimum isolation, 1.0 dB maximum insertion loss, and 14 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 10 W average power RF circulator supports up to 30 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 4 K and has a maximum weight of 0.9 oz, supporting stable RF performance in ultra-low temperature cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female...
D3C7012Y-4KD3C7012Y-4K-1D3C7012Y-4K-2D3C7012Y-4K-3D3C7012Y-4K-4D3C7012Y-4K-5D3C7012Y-4K-6D3C7012Y-4K-7
D3C7018
RM3,798.00
The D3C7018 RF circulator operates across the 7.00–18.00 GHz frequency range. It provides 15 dB minimum isolation, 1.0 dB maximum insertion loss, and 1.5:1 minimum VSWR to maintain controlled RF signal transmission within the specified frequency band.This 5 W average power RF circulator supports up to 30 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing and protection. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, brass load body, and nickel plated CRS magnetic shunt.The circulator operates within -10°C to +85°C and has a maximum weight of 0.9 oz, supporting reliable operation in RF and microwave environments.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C7018-1.
D3C7018D3C7018-1D3C7018-2D3C7018-3D3C7018-4D3C7018-5D3C7018-6D3C7018-7
D3C7510
RM2,661.00
The D3C7510 RF circulator operates across the 7.50–10.00 GHz frequency range. It provides 20 dB minimum isolation, 0.5 dB maximum insertion loss, and 1.25:1 minimum VSWR to maintain controlled RF signal transmission within the specified frequency band.This 10 W average power RF circulator supports up to 50 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing and protection. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, brass load body, and nickel plated CRS magnetic shunt.The circulator operates within -30°C to +65°C and has a maximum weight of 0.9 oz, supporting reliable performance in RF and microwave environments.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C7510-1.
D3C7510D3C7510-1D3C7510-2D3C7510-3D3C7510-4D3C7510-5D3C7510-6D3C7510-7
D3C7711Y-77K
RM13,920.00
The D3C7711Y-77K RF circulator operates across the 7.70–10.70 GHz frequency range. It provides 21 dB minimum isolation, 0.3 dB maximum insertion loss, and 18 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 10 W average power RF circulator supports up to 30 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 77 K and has a maximum weight of 0.9 oz, supporting stable RF performance in cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C7711Y-77K-1.
D3C7711Y-77KD3C7711Y-77K-1D3C7711Y-77K-2D3C7711Y-77K-3D3C7711Y-77K-4D3C7711Y-77K-5D3C7711Y-77K-6D3C7711Y-77K-7
D3C7784
RM2,661.00
The D3C7784 RF circulator operates across the 7.70–8.40 GHz frequency range. It provides 23 dB minimum isolation, 0.3 dB maximum insertion loss, and 1.2:1 minimum VSWR to maintain controlled RF signal transmission within the specified frequency band.This 10 W average power RF circulator supports up to 50 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing and protection. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, brass load body, and nickel plated CRS magnetic shunt.The circulator operates within -30°C to +65°C and has a maximum weight of 0.9 oz, supporting reliable operation in RF and microwave environments.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C7784-1.
D3C7784D3C7784-1D3C7784-2D3C7784-3D3C7784-4D3C7784-5D3C7784-6D3C7784-7
D3C8012
RM2,661.00
The D3C8012 RF circulator operates across the 8.00–12.40 GHz frequency range. It provides 20 dB minimum isolation, 0.5 dB maximum insertion loss, and 1.25:1 minimum VSWR to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing and protection. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, brass load body, and nickel plated CRS magnetic shunt.The circulator operates within -30°C to +85°C and has a maximum weight of 1.0 oz, supporting reliable operation in RF and microwave environments.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C8012-1.
D3C8012D3C8012-1D3C8012-2D3C8012-3D3C8012-4D3C8012-5D3C8012-6D3C8012-7
D3C8012Y-4K
RM10,629.00
The D3C8012Y-4K RF circulator operates across the 8.00–12.00 GHz frequency range. It provides 20 dB minimum isolation, 0.4 dB maximum insertion loss, and 20 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 4 K and has a maximum weight of 1.0 oz, supporting stable RF performance in ultra-low temperature cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female...
D3C8012Y-4KD3C8012Y-4K-1D3C8012Y-4K-2D3C8012Y-4K-3D3C8012Y-4K-4D3C8012Y-4K-5D3C8012Y-4K-6D3C8012Y-4K-7
D3C8012Y-77K
RM10,126.00
The D3C8012Y-77K RF circulator operates across the 8.00–12.00 GHz frequency range. It provides 22 dB minimum isolation, 0.3 dB maximum insertion loss, and 20 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is optimized for operation below 77 K and has a maximum weight of 1.0 oz, supporting stable RF performance in cryogenic systems.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female / Female = D3C8012Y-77K-1.
D3C8012Y-77KD3C8012Y-77K-1D3C8012Y-77K-2D3C8012Y-77K-3D3C8012Y-77K-4D3C8012Y-77K-5D3C8012Y-77K-6D3C8012Y-77K-7
D3C8012YMG-4K
RM11,135.00
The D3C8012YMG-4K RF circulator operates across the 8.00–12.00 GHz frequency range. It provides 20 dB minimum isolation, 0.4 dB maximum insertion loss, and 20 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is magnetically shielded and optimized for operation below 4 K, supporting stable RF performance in ultra-low temperature cryogenic systems. The unit has a maximum weight of 1.0 oz.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male...
D3C8012YMG-4KD3C8012YMG-4K-1D3C8012YMG-4K-2D3C8012YMG-4K-3D3C8012YMG-4K-4D3C8012YMG-4K-5D3C8012YMG-4K-6D3C8012YMG-4K-7
D3C8012YMG-77K
RM10,629.00
The D3C8012YMG-77K RF circulator operates across the 8.00–12.00 GHz frequency range. It provides 22 dB minimum isolation, 0.3 dB maximum insertion loss, and 20 dB minimum return loss to maintain controlled RF signal transmission within the specified frequency band.This 25 W average power RF circulator supports up to 500 W peak forward power, making it suitable for RF and microwave systems requiring efficient signal routing in cryogenic environments. The unit features an SMA connector interface with a passivated stainless steel connector body, gold plated copper connector pin, and nickel plated CRS magnetic shunt.The circulator is magnetically shielded and optimized for operation below 77 K, supporting stable RF performance in cryogenic systems. The unit has a maximum weight of 1.0 oz.This model is available in multiple connector configurations. Select the appropriate option based on the required connector gender for Port 1 / Port 2 / Port 3. Example: Male / Female...
D3C8012YMG-77KD3C8012YMG-77K-1D3C8012YMG-77K-2D3C8012YMG-77K-3D3C8012YMG-77K-4D3C8012YMG-77K-5D3C8012YMG-77K-6D3C8012YMG-77K-7